A novel minimally invasive, dorsolateral, tubular partial odontoidectomy and autologous bone augmentation to treat dens pseudarthrosis: cadaveric, 3D…

2017

OBJECTIVE The goal of this study was to demonstrate the clinical and technical nuances of a minimally invasive, dorsolateral, tubular approach for partial odontoidectomy, autologous bone augmentation, and temporary C1–2 fixation to treat dens pseudarthrosis. METHODS A cadaveric feasibility study, a 3D virtual reality reconstruction study, and the subsequent application of this approach in 2 clinical cases are reported. Eight procedures were completed in 4 human cadavers. A minimally invasive, dorsolateral, tubular approach for odontoidectomy was performed with the aid of a tubular retraction system, using a posterolateral incision and an oblique approach angle. Fluoroscopy and postprocedur…

AdultMaleModels Anatomicmedicine.medical_specialtyBone ScrewsRadiography Interventional03 medical and health sciencesUser-Computer InterfaceYoung Adult0302 clinical medicineImaging Three-DimensionalCadaverPars interarticularismedicineCadaverFluoroscopyHumansComputer SimulationOrthopedic ProceduresFixation (histology)030222 orthopedicsmedicine.diagnostic_testbusiness.industryGeneral Medicinemedicine.diseaseSurgeryPseudarthrosisPseudarthrosismedicine.anatomical_structureFluoroscopyCervical VertebraeFeasibility StudiesSpinal FracturesOrthopedic ProceduresCadaveric spasmbusinessTomography X-Ray Computed030217 neurology & neurosurgeryCervical vertebraeJournal of neurosurgery. Spine
researchProduct

Do palatal implants remain positionally stable under orthodontic load? A clinical radiologic study.

2009

Introduction The aim of this study was to determine the positional stability and success rate of palatally placed length-reduced temporary anchorage devices (LRTADs) (length, 4 or 6 mm). Methods Twenty-two patients (ages, 21-62 years; 14 women, 8 men) were enrolled in the study. Each received 1 LRTAD (Orthosystem, Straumann, Switzerland) placed in the midsagittal palate for multifunctional anchorage tasks. Standardized cephalograms were taken directly after implant placement and at the end of treatment to analyze any implant movements. The cephalometric tracings were superimposed on anterior nasal spine to posterior nasal spine in posterior nasal spine to analyze changes in implant angulati…

AdultMaleTime FactorsTooth Movement TechniquesCephalometryBone ScrewsDentistryOrthodonticsOsseointegrationWeight-BearingYoung AdultOsseointegrationmedicineOrthodontic Anchorage ProceduresHumansOrthodontic Appliance DesignLongitudinal StudiesOrthodonticsDental Implantsbusiness.industryPalateDental Implantation EndosseousAnterior nasal spineCraniometryMiddle Agedmedicine.diseaseOrthodontic Anchorage ProceduresRadiographymedicine.anatomical_structureMaxillaFemaleImplantStress MechanicalMalocclusionPosterior nasal spinebusinessMalocclusionAmerican journal of orthodontics and dentofacial orthopedics : official publication of the American Association of Orthodontists, its constituent societies, and the American Board of Orthodontics
researchProduct

Intraoperative C-arm CT imaging in angular stable plate osteosynthesis of distal radius fractures

2013

The purpose of this study was to analyze the practicability and benefit of intraoperative C-arm computed tomography (CT) imaging in volar plate osteosynthesis of unstable distal radius fractures. During a 1 year period, intraoperative three dimensional (3D) imaging with the ARCADIS Orbic 3D was performed in addition to standard fluoroscopy in 51 cases. The volar angular stable plate oesteosyntheses were analyzed intraoperatively and, if necessary, improved immediately. The duration of the scan and radiation exposure dose were measured. On average, performance of the scan and analysis of the CT dataset took 6.7 minutes. In 31.3% of the surgeries a misplacement of screws was detected and cor…

AdultMalemedicine.medical_specialtyBone ScrewsComputed tomographyRadiation DosageFracture Fixation InternalIntraoperative PeriodImaging Three-DimensionalmedicineHumansFluoroscopyProspective StudiesAgedDigital radiographyAged 80 and overOsteosynthesismedicine.diagnostic_testbusiness.industryRadiusMiddle AgedRadiation exposureTreatment OutcomePlate osteosynthesisFluoroscopyFemaleSurgeryRadiologyCt imagingRadius FracturesTomography X-Ray ComputedbusinessBone PlatesJournal of Hand Surgery (European Volume)
researchProduct

Customized approach for otogenic brain abscess: the neurosurgical prospective.

2017

Bone Screws Decompression Surgical Humans Minimally Invasive Surgical Procedures Lumbosacral Region Neurosurgical Procedures Spinal Stenosis
researchProduct

Osteosynthesetechniken bei proximalen Humerusfrakturen

2001

Proximale Humerusfrakturen sind haufige Verletzungen. Die Frage der optimalen osteosynthetischen Behandlung instabiler und dislozierter 2- bis 4-Segmentfrakturen ist nach wie vor nicht einhellig geklart. Die operative Therapie befindet sich in der Konfliktsituation zwischen der Forderung einer anatomischen Reposition und stabilen Frakturretention auf der einen Seite und der Notwendigkeit einer maximalen intraoperativen Schonung der periglenohumeralen Weichteilstrukturen und Blutversorgung des Oberarmkopfs, mit dem Ziel das iatrogene Risiko der avascularen Kopfnekrose zu minimieren, andererseits. Wahrend Minimalosteosynthesen, bei denen die Reposition indirekt oder percutan erfolgt, Vorteile…

Bone screwsGynecologymedicine.medical_specialtyTransplant surgeryOsteosynthesisCardiothoracic surgerybusiness.industryFracture fixationBone platemedicineSurgerybusinessAbdominal surgeryDer Chirurg
researchProduct

Zur erweitrten Indikationsstellung der Herbert-Schrauben-Osteosynthese

1995

Since 1984 the typical headless double threaded Herbert/Whipple screw is known in managing scaphoid fractures and scaphoid non-unions. We resume technical, biomechanical and histological aspects to point out advantages and disadvantages of this osteosynthesis. Our case review of 39 patients illustrate the same good results as achieved in treating scaphoid injuries, when using the Herbert/Whipple screw of a larger diameter for expanded indications other than scaphoid fractures, such as humeral- or radial-head fractures, Jones fractures and others.

Bone screwsOrthodonticsCarpal bonesmedicine.anatomical_structureOsteosynthesisbusiness.industrymedicineSurgeryKnee injuriesbusinessCase reviewWrist injuryHerbert screwUnfallchirurgie
researchProduct

Are there any differences in various polyaxial locking systems? A mechanical study of different locking screws in multidirectional angular stable dis…

2012

Numerous angular stable plates for the distal radius exist, and technically based comparisons of the polyaxial locking interfaces are lacking. The aim of this mechanical study was to investigate three different locking interfaces of angular stable volar plates by cantilever bending: VA-LCP Two-Column Distal Radius Plates 2.4 mm (Synthes® GmbH, Oberdorf, Switzerland), IXOS® P4 (Martin, Tuttlingen, Germany) and VariAX™ (Stryker®, Duisburg, Germany). We assessed the strength of 0°, 5°, 10° and 15° screw locking angles and tested the bending strength from 10° to 5° angles by cyclic loading until breakage. The final setup repeated the above assessments by inclusion of four locking screws. The si…

Compressive StrengthFrictionbusiness.industryBone ScrewsBiomedical EngineeringRadiusStructural engineeringProsthesis DesignInternal FixatorsMechanism (engineering)Equipment Failure AnalysisCompressive strengthFlexural strengthBreakageElastic ModulusTensile StrengthBone plateUltimate tensile strengthBending momentHumansbusinessRadius FracturesBone PlatesBiomedizinische Technik. Biomedical engineering
researchProduct

Osseointegration of miniscrews: a histomorphometric evaluation.

2007

SUMMARY Mini-implants and miniscrews are commonly used in orthodontics to provide additional temporary intraoral anchorage. Partial osseointegration represents a distinct advantage in orthodontic applications, allowing effective anchorage to be combined with easy insertion and removal. This article reports the histomorphometric fi ndings of the osseointegration of bracket screw bone anchors (BSBAs). In an experimental animal study, four BSBAs were inserted in the alveolar process of the lower jaw in each of fi ve male beagle dogs, aged 6.5 months from the same mother. Eleven screws were lost during the study, nine of them due to lack of primary stability. One screw was removed at the end of…

Dental Stress AnalysisMaleTime FactorsBone ScrewsDentistryMandibleBone anchorhistomorphometryOsseointegrationStatistics NonparametricDogsImplants ExperimentalOsseointegrationIndependent samplesAlveolar ProcessOrthodontic Anchorage ProceduresMedicineAnimalsOrthodonticsMiniaturizationbusiness.industryAlveolar processBracketMandibleExperimental animalmedicine.anatomical_structureDental Stress Analysismini screwsEquipment FailurebusinessorthodonticsEuropean journal of orthodontics
researchProduct

Locking Reconstruction Double Plating of Distal Humeral Fractures: How Many Screws in the Distal Ulnar Column Segment in A3 Fracture Provide Superior…

2009

Objectives: Two 90-degree configurations of locking reconstruction plates with different numbers of screws in the distal ulnar column segment of distal extra-articular humeral fractures with metaphyseal comminution (A3) were biomechanically investigated. Methods: Eight pairs of fresh-frozen human humeri were used. For paired comparison, the humeri were divided into 2 randomized groups. In both groups, double-plate osteosyntheses with locking reconstruction plates were performed in 90-degree configurations. In group 1, the posteriorly placed radial column plate exceeded the capitellum and the ulnar column plate extended into the ulnar sulcus. The ulnar plate was molded around the medial epic…

Joint InstabilityMalemusculoskeletal diseasesHumeral Fracturesmedicine.medical_specialtyCompressive StrengthBone ScrewsUlnaBendingWeight-BearingElastic ModulusProsthesis FittingTensile StrengthElbow JointmedicineHumansOrthopedics and Sports MedicineHumerusAged 80 and overOrthodonticsOsteosynthesisbusiness.industryBiomechanicsStiffnessGeneral MedicineMiddle Agedmusculoskeletal systemSurgeryTreatment Outcomemedicine.anatomical_structureFracture (geology)FemaleSurgeryImplantmedicine.symptomElbow InjuriesEpicondylebusinessBone PlatesJournal of Orthopaedic Trauma
researchProduct

Metacarpophalangeal joint of the thumb arthrodesis using intramedullary interlocking screws XMCP™

2018

Abstract The study objective was to assess the results of a thumb metacarpophalangeal joint (MCPJ) arthrodesis using intramedullary interlocking screws at 25°, XMCP ™ (Extremity Medical, Parsippany, NJ). Radiographs evaluated the angle of arthrodesis, time of fusion and fixation of the implant. Clinical and functional outcomes were assessed using the DASH questionnaire and the VAS scale. Any complications found during surgery or the follow-up period were noted. We studied 9 patients. The mean follow-up was 27.6 months. Patients showed clinical and radiological evidence of fusion in an average of 8 weeks, the angle of fusion was 25°. There were no complications and no implant had to be remov…

MaleArthrodesismedicine.medical_treatmentRadiographyBone ScrewsArthrodesisThumblaw.inventionArthritis RheumatoidMetacarpophalangeal JointIntramedullary rod03 medical and health sciencesFixation (surgical)0302 clinical medicinelawmedicineHumansOrthopedics and Sports Medicine030212 general & internal medicineAgedOrthodontics030222 orthopedicsbusiness.industryArthrodesis Arthrosis Articulación metacarpofalángica Artritis reumatoide Artrodesis Artrosis Metacarpophalangeal joint Rheumatoid arthritisMetacarpophalangeal jointMiddle AgedTreatment Outcomemedicine.anatomical_structureThumbRadiological weaponFemaleSurgeryImplantJoint DiseasesbusinessFollow-Up StudiesRevista Española de Cirugía Ortopédica y Traumatología (English Edition)