Search results for "Bone Screws"
showing 10 items of 33 documents
A novel minimally invasive, dorsolateral, tubular partial odontoidectomy and autologous bone augmentation to treat dens pseudarthrosis: cadaveric, 3D…
2017
OBJECTIVE The goal of this study was to demonstrate the clinical and technical nuances of a minimally invasive, dorsolateral, tubular approach for partial odontoidectomy, autologous bone augmentation, and temporary C1–2 fixation to treat dens pseudarthrosis. METHODS A cadaveric feasibility study, a 3D virtual reality reconstruction study, and the subsequent application of this approach in 2 clinical cases are reported. Eight procedures were completed in 4 human cadavers. A minimally invasive, dorsolateral, tubular approach for odontoidectomy was performed with the aid of a tubular retraction system, using a posterolateral incision and an oblique approach angle. Fluoroscopy and postprocedur…
Do palatal implants remain positionally stable under orthodontic load? A clinical radiologic study.
2009
Introduction The aim of this study was to determine the positional stability and success rate of palatally placed length-reduced temporary anchorage devices (LRTADs) (length, 4 or 6 mm). Methods Twenty-two patients (ages, 21-62 years; 14 women, 8 men) were enrolled in the study. Each received 1 LRTAD (Orthosystem, Straumann, Switzerland) placed in the midsagittal palate for multifunctional anchorage tasks. Standardized cephalograms were taken directly after implant placement and at the end of treatment to analyze any implant movements. The cephalometric tracings were superimposed on anterior nasal spine to posterior nasal spine in posterior nasal spine to analyze changes in implant angulati…
Intraoperative C-arm CT imaging in angular stable plate osteosynthesis of distal radius fractures
2013
The purpose of this study was to analyze the practicability and benefit of intraoperative C-arm computed tomography (CT) imaging in volar plate osteosynthesis of unstable distal radius fractures. During a 1 year period, intraoperative three dimensional (3D) imaging with the ARCADIS Orbic 3D was performed in addition to standard fluoroscopy in 51 cases. The volar angular stable plate oesteosyntheses were analyzed intraoperatively and, if necessary, improved immediately. The duration of the scan and radiation exposure dose were measured. On average, performance of the scan and analysis of the CT dataset took 6.7 minutes. In 31.3% of the surgeries a misplacement of screws was detected and cor…
Customized approach for otogenic brain abscess: the neurosurgical prospective.
2017
Osteosynthesetechniken bei proximalen Humerusfrakturen
2001
Proximale Humerusfrakturen sind haufige Verletzungen. Die Frage der optimalen osteosynthetischen Behandlung instabiler und dislozierter 2- bis 4-Segmentfrakturen ist nach wie vor nicht einhellig geklart. Die operative Therapie befindet sich in der Konfliktsituation zwischen der Forderung einer anatomischen Reposition und stabilen Frakturretention auf der einen Seite und der Notwendigkeit einer maximalen intraoperativen Schonung der periglenohumeralen Weichteilstrukturen und Blutversorgung des Oberarmkopfs, mit dem Ziel das iatrogene Risiko der avascularen Kopfnekrose zu minimieren, andererseits. Wahrend Minimalosteosynthesen, bei denen die Reposition indirekt oder percutan erfolgt, Vorteile…
Zur erweitrten Indikationsstellung der Herbert-Schrauben-Osteosynthese
1995
Since 1984 the typical headless double threaded Herbert/Whipple screw is known in managing scaphoid fractures and scaphoid non-unions. We resume technical, biomechanical and histological aspects to point out advantages and disadvantages of this osteosynthesis. Our case review of 39 patients illustrate the same good results as achieved in treating scaphoid injuries, when using the Herbert/Whipple screw of a larger diameter for expanded indications other than scaphoid fractures, such as humeral- or radial-head fractures, Jones fractures and others.
Are there any differences in various polyaxial locking systems? A mechanical study of different locking screws in multidirectional angular stable dis…
2012
Numerous angular stable plates for the distal radius exist, and technically based comparisons of the polyaxial locking interfaces are lacking. The aim of this mechanical study was to investigate three different locking interfaces of angular stable volar plates by cantilever bending: VA-LCP Two-Column Distal Radius Plates 2.4 mm (Synthes® GmbH, Oberdorf, Switzerland), IXOS® P4 (Martin, Tuttlingen, Germany) and VariAX™ (Stryker®, Duisburg, Germany). We assessed the strength of 0°, 5°, 10° and 15° screw locking angles and tested the bending strength from 10° to 5° angles by cyclic loading until breakage. The final setup repeated the above assessments by inclusion of four locking screws. The si…
Osseointegration of miniscrews: a histomorphometric evaluation.
2007
SUMMARY Mini-implants and miniscrews are commonly used in orthodontics to provide additional temporary intraoral anchorage. Partial osseointegration represents a distinct advantage in orthodontic applications, allowing effective anchorage to be combined with easy insertion and removal. This article reports the histomorphometric fi ndings of the osseointegration of bracket screw bone anchors (BSBAs). In an experimental animal study, four BSBAs were inserted in the alveolar process of the lower jaw in each of fi ve male beagle dogs, aged 6.5 months from the same mother. Eleven screws were lost during the study, nine of them due to lack of primary stability. One screw was removed at the end of…
Locking Reconstruction Double Plating of Distal Humeral Fractures: How Many Screws in the Distal Ulnar Column Segment in A3 Fracture Provide Superior…
2009
Objectives: Two 90-degree configurations of locking reconstruction plates with different numbers of screws in the distal ulnar column segment of distal extra-articular humeral fractures with metaphyseal comminution (A3) were biomechanically investigated. Methods: Eight pairs of fresh-frozen human humeri were used. For paired comparison, the humeri were divided into 2 randomized groups. In both groups, double-plate osteosyntheses with locking reconstruction plates were performed in 90-degree configurations. In group 1, the posteriorly placed radial column plate exceeded the capitellum and the ulnar column plate extended into the ulnar sulcus. The ulnar plate was molded around the medial epic…
Metacarpophalangeal joint of the thumb arthrodesis using intramedullary interlocking screws XMCP™
2018
Abstract The study objective was to assess the results of a thumb metacarpophalangeal joint (MCPJ) arthrodesis using intramedullary interlocking screws at 25°, XMCP ™ (Extremity Medical, Parsippany, NJ). Radiographs evaluated the angle of arthrodesis, time of fusion and fixation of the implant. Clinical and functional outcomes were assessed using the DASH questionnaire and the VAS scale. Any complications found during surgery or the follow-up period were noted. We studied 9 patients. The mean follow-up was 27.6 months. Patients showed clinical and radiological evidence of fusion in an average of 8 weeks, the angle of fusion was 25°. There were no complications and no implant had to be remov…